# Pylontech cell voltage: what's normal, and what isn't

> Normal Pylontech cell voltages at rest and while charging, what cell spread to expect, and when a low cell is worth a call to your installer. With a quick chart.

Source: https://pylontech-viewer.com/pylontech-cell-voltage · Updated 2026-11-28

Once a viewer shows you all 15 cells, the obvious question is whether those numbers are fine. Here are the ranges we look at when we read a Pylontech battery, and the patterns that deserve attention.

## The chemistry in one paragraph

Pylontech home batteries use lithium iron phosphate (LFP) cells. A US2000C, US3000C or US5000 has 15 of them in series, which is why the pack sits around 48 to 53 V. LFP has a very flat voltage curve: across most of the charge range a cell barely moves between about 3.25 and 3.35 V. That's great for stable power and awkward for guessing the charge from voltage alone.

## Approximate cell voltage at rest

These are typical values for an LFP cell that has rested for a while (no charge or discharge for 30 minutes or more), at room temperature. Treat them as a rough guide: temperature, age and the last few hours of use all shift them a little. The battery's own state of charge figure, shown in the viewer, is more reliable than this table.

| Cell voltage at rest | Pack (15 cells) | Roughly means |
| --- | --- | --- |
| 3.40 V and above | about 51 V and above | Full or very close to it |
| 3.33 – 3.35 V | about 50 V | Well charged |
| 3.28 – 3.32 V | about 49.5 V | The long flat middle of the range |
| 3.20 – 3.25 V | about 48.3 V | Getting low |
| Below 3.10 V | below about 46.5 V | Nearly empty; the BMS will soon limit discharge |

## While charging and discharging

Under load the numbers move: cells read higher while charging and lower while discharging, more so at high current. Near the end of a charge they climb quickly towards 3.45–3.5 V, and that's also when the cells drift apart for a moment and the BMS starts balancing. A brief spread at the very top of a charge is normal. What matters is what happens once the battery rests.

## Cell spread: the number to watch

The spread is the gap between the highest and lowest cell of one battery (Vhigh minus Vlow in the console). It tells you more about battery health than any single voltage.

  - **Under about 30 mV at rest**: healthy and well balanced.

  - **30 to 100 mV**: keep an eye on it. It often shrinks after a few full charges, because balancing only really happens near full.

  - **Over 100 mV at rest, or getting worse week after week**: write the numbers down and show them to your installer.

## Patterns worth noticing

  - **The same cell number is always the lowest.** One weak cell sets the pace for the whole battery: it reaches empty first and full last.

  - **One battery in the stack always ends the evening lower.** Often a connection, cabling or balancing matter rather than a dead battery, and worth raising early.

  - **The spread only looks bad when the battery is nearly empty or nearly full.** That's usually fine: LFP cells separate at both ends of the curve.

## Seeing your own numbers

The [free online viewer](https://pylontech-viewer.com/online-viewer) shows every cell of the master battery with the lowest and highest highlighted. To follow the spread day after day, the Pylon-Monitor V3 keeps 3 years of history and shows it on your phone, from anywhere.

## Questions people ask

### What is a normal cell voltage for a Pylontech battery?

At rest, most of the time between about 3.25 and 3.35 V per cell. Near full it rises towards 3.4 V and above; below about 3.1 V the battery is nearly empty.

### What cell spread is acceptable on a Pylontech?

Under about 30 mV at rest is healthy. Between 30 and 100 mV, keep an eye on it; above 100 mV at rest, or a spread that keeps growing, is worth showing to your installer.

### Can I tell the state of charge from the cell voltage?

Only roughly, because LFP cells have a very flat curve. The state of charge reported by the battery itself is more reliable.

---
Pylontech-Viewer.com is an independent website. It is not affiliated with, endorsed, sponsored or approved by Pylon Technologies Co., Ltd. Pylontech®, BatteryView and the model names US2000, US3000, US5000, UP5000 and Force are trademarks or product names of their owner, used only to describe compatibility. No Pylontech software is hosted here.